Instruments for Femoral Heads

Total: (15)

Bone Skid Murphy Lane

Bone Skid Murphy Lane

Model No: FHI42

Description: The GPC Bone Skid Murphy Lane is used for extracting the femoral head during hemi arthroplasty or total hip replacement or for inserting the head....

Hooks for Head Extractor

Hooks for Head Extractor

Model No: FHI44

Description: The GPC hook is used for retracting the greater trochanter while doing hemi arthroplasty. ...

Gauge for Prosthesis, set of nine

Gauge for Prosthesis, set of nine

Model No: FHI46

Description: The GPC Gauge for prosthesis, set of nine is used for measuring the removed femoral head to determine the size of the implant to be put during hemi arthroplasty. ...

Hollow Chisel, Austin Moore type

Hollow Chisel, Austin Moore type

Model No: FHI47

Description: The GPC Hollow chisel, Austin Moore type is used to make the entry point of the femoral implant during hemi arthroplasty....

Impactor for Femoral Head Tufnol faced Aluminum

Impactor for Femoral Head Tufnol faced Aluminum

Model No: FHI51

Description: The GPC Impactor for femoral head, aluminium is used to reduce the femoral hemiarthroplasty implant into the acetabulum....

Judet Auger Extractor S.S.

Judet Auger Extractor S.S.

Model No: FHI53

Description: The GPC Judet Auger Extractor S.S is used to extract the femoral head during hemi arthroplasty. It has a cork screw which can be screwed into the femoral head during...

Rasp. Moore Type Tommy Bar

Rasp. Moore Type Tommy Bar

Model No: FHI54

Description: The GPC Rasp Moore type with tommy bar is used for rasping the femoral canal for Austin moore prosthesis....

Rasp. Thompson Type with Tommy Bar

Rasp. Thompson Type with Tommy Bar

Model No: FHI55

Description: The GPC Rasp Thompson type with tommy bar is used for rasping the femoral canal for thompsons prosthesis....

Rasp Moore type-Extra long

Rasp Moore type-Extra long

Model No: FHI56

Description: The GPC Rasp Moore type extra long is used for rasping of the femoral canal when long stem Austin moore is used....

Bi-Polar Rasp

Bi-Polar Rasp

Model No: FHI57

Description: The GPC Bipolar rasp is used for rasping of the femoral canal when bipolar prosthesis is used....

Extractor Set for Austin Moore Prosthesis with 2 Hooks

Extractor Set for Austin Moore Prosthesis with 2 Hooks

Model No: FHI58

Description: The GPC Extractor set for austin moore prosthesis is used for extracting the implanted Austin moore prosthesis....

Judet Retractor

Judet Retractor

Model No: FHI59

Description: The GPC Judet retractor is used for retraction of the soft tissues during hemi arthroplasty....

Putty Rasp

Putty Rasp

Model No: FHI60

Description: The GPC putty rasp is used for making the entry into the femoal canal after the hollow chisel has been used.The putty rasp can also be used for making sure...

Austin Moore Impactor

Austin Moore Impactor

Model No: FHI62

Description: The GPC Austin moore impactor is used for impacting the austin moore implant into the femoral canal. ...

Bone File, Fibre Handle

Bone File, Fibre Handle

Model No: FHI64

Description: The GPC Bone file, fibre handle is used for smoothing any rough edges of the femoral neck before insertion of the implant. It can also be used for smoothing any...

Total: (15)



.

Request a FREE Quote NOW!